€2,844.22 incl. VAT
pcs
Item description
Application:
The pressure booster increases the input pressure to the value set on the control valve. The outlet pressure can measure max. four or. 2two times the input pressure, but can never exceed the max. outlet pressure. Should an individual consumer (clamping cylinder etc.) be operated with a pressure higher than the standard network pressure, the pressure booster can accordingly increase the supply pressure for this single consumer. An installed pressure regulator maintains a constant working pressure (with less pulsation).

Advantages:
High energy saving and no electrical energy necessary directly on consumer. For a further consumer, it is not necessary to pretension the entire compressed air network to a higher level.

Installation recommendation:
In order to reduce the pressure pulsation on the secondary side, we recommend creating an additional volume in the form of a container. If the volume of the serially connected air duct is insufficient, we recommend the container volumes given in the table.

Media:
Filtered, unoiled compressed air

Installation position:
horizontal

Temperature range:
+5 to +50 °C

Pressure gauge connection:
R 1/8" (conical)

Warning:
Order accessories at the same time! Please order silencers and pressure gauges separately!
Properties
Gear ra­tion max. 2 : 1
Out­let pres­sure [bar] 2 - 16
Flow ca­pac­ity* [l/min] 1.600
Con­nec­tion thread G 1/2"
Pres­sure gauge con­nec­tion R 1/8"
Rec­om­mended con­tainer vol­ume [LTR] 30 - 50
Ac­ces­sories pres­sure gauges MW 2540
Wear part set DUE 1600 A REP
Further information on DUE1600A
Weight 9 kg / pcs
GTIN 4050571276812
Customs duty number 84148028
Documents
*Measured at 5 bar input and outlet pressure. Please note: The greater the pressure increase of P1 to secondary P2 set at the regulator, the lower the available volume flow rate, such.as. the DUE 230 A achieves a 100 litre per second supply amount at 8 bar outlet pressure if the input pressure is 5 bar. We would be happy to provide you with the flow-rate characteristics if needed.

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Immediately available
Payment options:

Cash on delivery

Invoice